MPO/MTP Adapter Panel & Patch Enclosure

SKU: FOT-MPO-PANEL · Cassettes, Modules & Panels

LGX adapter plates and 1U/2U enclosures for MPO patching.

12 portsMPO adapters
LGXStandard plate
Key-up/key-downAdapter orientation
ShutteredDust protection
Ports
12 × MPO6 × MPO8 × MPO16 × MPO24 × MPO
Polish
APC (angled, 8°)UPC / PC (flat)
Adapter orientation
Key-up / key-down (Type A)Key-up / key-up (Type B)
Shutter
ShutteredOpen (no shutter)
Format
LGX adapter plate1U 19" enclosure (4 plates)2U 19" enclosure (8 plates)Wall-mount enclosure
Configured part numberFOT-MPO-PANEL
Ships worldwide
Built to your configuration
3-year warranty

Product Overview

The plain pass-through option: a plate of MPO adapters that lets a trunk terminate at the panel and a jumper carry on from there. No fibre routing inside, nothing to go wrong, and it keeps the expensive trunk connector out of daily handling.

Assemblies are built on US Conec MTP® ferrules and terminated in a controlled environment, then measured fibre by fibre. Interferometry checks the three geometry parameters that decide whether a multi-fibre ferrule mates properly — radius of curvature, apex offset and fibre height — and every end face is inspected and graded to IEC 61300-3-35 before the dust cap goes on.

Fibre count, fibre type, polish, polarity, gender, jacket rating, leg length and overall length are all build options rather than catalogue limits. Use the selector above to configure the exact assembly and the specification table will follow your choices; the measured test report ships with the cable.

Technical SpecificationsUpdates with your selection

Optical
Ports12 × MPO adapters
Connector PolishAPC — 8° angled, green housing
Insertion LossAdapter contributes ≤ 0.10 dB (mated pair loss set by the connectors)
Adapter OrientationKey-up to key-down (Type A convention)
Return Loss≥ 60 dB
Mechanical & Environment
FormatLGX-compatible adapter plate
Adapter BodyThermoplastic with metal alignment sleeve retention
ShutterFitted — protects ferrules from dust when unmated
HousingCold-rolled steel, black powder coat
LabellingPort numbering plus writable label strip
Operating Temp-10 °C to +60 °C
ComplianceIEC 61754-7, TIA-604-5, RoHS
Testing, Quality & Supply
Optical Test100% — every fibre measured for insertion loss and return loss before shipment
Ferrule GeometryInterferometer-verified: radius of curvature, apex offset and fibre height to IEC 61755-3
End-Face InspectionEvery ferrule inspected and graded to IEC 61300-3-35
Test ReportPer-fibre measured data supplied with the assembly, traceable to the serial number
Connector SourceUS Conec MTP® ferrules; genuine-brand or FOT MPO to your preference
CustomisationFibre count, type, polish, polarity, gender, jacket, leg length and overall length built to order
Lead TimeStock configurations 3–5 days; custom builds 7–10 days
Warranty3 years

Ordering Information

Part NumberConfigurationFibre countAvailability
FOT-MPO-PANELStandard configuration—Build to order
FOT-MPO-PANEL-6PPorts: 6 × MPO—Build to order
FOT-MPO-PANEL-8PPorts: 8 × MPO—Build to order
FOT-MPO-PANEL-16PPorts: 16 × MPO—Build to order
FOT-MPO-PANEL-24PPorts: 24 × MPO—Build to order
FOT-MPO-PANEL-UPCPolish: UPC / PC (flat)—Build to order

Part numbers are indicative. Send us the fibre count, type, polish, polarity, gender, jacket and length and we confirm the exact build code on the quotation.

Quality & What's in the Box

Measured Fibre by Fibre

Insertion loss and return loss recorded for every fibre, not sampled.

Geometry Verified

Interferometer data on ferrule radius, apex offset and fibre height.

Inspected & Graded

Every end face checked against IEC 61300-3-35 before packing.

Packaging

Dust-capped, coiled on a reel or in a bag with the test report and pulling sock.

Typical Applications

Data Centre Spine & Leaf

Parallel 40G/100G/400G/800G backbone between spine, leaf and top-of-rack panels.

AI / GPU Clusters

Rail-optimised accelerator fabrics where one switch port breaks out to several GPUs.

Structured Cabling

Pre-terminated backbone that installs in hours instead of days, with the loss budget known up front.

Test & Commissioning

Loopbacks, attenuators and inspection for proving ports before the link goes live.

Frequently Asked Questions

Key-up/key-down or key-up/key-up — does it matter?

Very much. The adapter orientation is part of the polarity scheme: a Type A channel expects key-up to key-down adapters, a Type B channel expects key-up to key-up. Get it wrong and the channel is crossed. Decide the scheme for the whole site, write it down, and order every plate the same.

Should I specify shuttered adapters?

For anything that will sit unmated in a live room, yes. An unshuttered MPO adapter collects dust straight onto the ferrule, and a contaminated MPO ferrule is twelve dirty fibres at once. The shutter costs very little and saves a cleaning visit.

How is the assembly labelled?

Both ends carry a printed label with the part number, fibre count, fibre type, polarity type and the serial number, and breakout legs are individually numbered. Tell us your own labelling convention on the RFQ and we print to it — it costs nothing and it saves an afternoon at installation.

Can I get free samples before ordering volume?

Yes. We supply qualification samples so you can measure the loss and check the fit in your own panels before committing. Per-order test reports are standard, and sample reports can be provided in advance for tender documentation.