Enter for the full results page · Esc to close

LGX adapter plates and 1U/2U enclosures for MPO patching.
The plain pass-through option: a plate of MPO adapters that lets a trunk terminate at the panel and a jumper carry on from there. No fibre routing inside, nothing to go wrong, and it keeps the expensive trunk connector out of daily handling.
Assemblies are built on US Conec MTP® ferrules and terminated in a controlled environment, then measured fibre by fibre. Interferometry checks the three geometry parameters that decide whether a multi-fibre ferrule mates properly — radius of curvature, apex offset and fibre height — and every end face is inspected and graded to IEC 61300-3-35 before the dust cap goes on.
Fibre count, fibre type, polish, polarity, gender, jacket rating, leg length and overall length are all build options rather than catalogue limits. Use the selector above to configure the exact assembly and the specification table will follow your choices; the measured test report ships with the cable.
| Ports | 12 × MPO adapters |
|---|---|
| Connector Polish | APC — 8° angled, green housing |
| Insertion Loss | Adapter contributes ≤ 0.10 dB (mated pair loss set by the connectors) |
| Adapter Orientation | Key-up to key-down (Type A convention) |
| Return Loss | ≥ 60 dB |
| Format | LGX-compatible adapter plate |
|---|---|
| Adapter Body | Thermoplastic with metal alignment sleeve retention |
| Shutter | Fitted — protects ferrules from dust when unmated |
| Housing | Cold-rolled steel, black powder coat |
| Labelling | Port numbering plus writable label strip |
| Operating Temp | -10 °C to +60 °C |
| Compliance | IEC 61754-7, TIA-604-5, RoHS |
| Optical Test | 100% — every fibre measured for insertion loss and return loss before shipment |
|---|---|
| Ferrule Geometry | Interferometer-verified: radius of curvature, apex offset and fibre height to IEC 61755-3 |
| End-Face Inspection | Every ferrule inspected and graded to IEC 61300-3-35 |
| Test Report | Per-fibre measured data supplied with the assembly, traceable to the serial number |
| Connector Source | US Conec MTP® ferrules; genuine-brand or FOT MPO to your preference |
| Customisation | Fibre count, type, polish, polarity, gender, jacket, leg length and overall length built to order |
| Lead Time | Stock configurations 3–5 days; custom builds 7–10 days |
| Warranty | 3 years |
| Part Number | Configuration | Fibre count | Availability |
|---|---|---|---|
| FOT-MPO-PANEL | Standard configuration | — | Build to order |
| FOT-MPO-PANEL-6P | Ports: 6 × MPO | — | Build to order |
| FOT-MPO-PANEL-8P | Ports: 8 × MPO | — | Build to order |
| FOT-MPO-PANEL-16P | Ports: 16 × MPO | — | Build to order |
| FOT-MPO-PANEL-24P | Ports: 24 × MPO | — | Build to order |
| FOT-MPO-PANEL-UPC | Polish: UPC / PC (flat) | — | Build to order |
Part numbers are indicative. Send us the fibre count, type, polish, polarity, gender, jacket and length and we confirm the exact build code on the quotation.
Insertion loss and return loss recorded for every fibre, not sampled.
Interferometer data on ferrule radius, apex offset and fibre height.
Every end face checked against IEC 61300-3-35 before packing.
Dust-capped, coiled on a reel or in a bag with the test report and pulling sock.
Parallel 40G/100G/400G/800G backbone between spine, leaf and top-of-rack panels.
Rail-optimised accelerator fabrics where one switch port breaks out to several GPUs.
Pre-terminated backbone that installs in hours instead of days, with the loss budget known up front.
Loopbacks, attenuators and inspection for proving ports before the link goes live.
Very much. The adapter orientation is part of the polarity scheme: a Type A channel expects key-up to key-down adapters, a Type B channel expects key-up to key-up. Get it wrong and the channel is crossed. Decide the scheme for the whole site, write it down, and order every plate the same.
For anything that will sit unmated in a live room, yes. An unshuttered MPO adapter collects dust straight onto the ferrule, and a contaminated MPO ferrule is twelve dirty fibres at once. The shutter costs very little and saves a cleaning visit.
Both ends carry a printed label with the part number, fibre count, fibre type, polarity type and the serial number, and breakout legs are individually numbered. Tell us your own labelling convention on the RFQ and we print to it — it costs nothing and it saves an afternoon at installation.
Yes. We supply qualification samples so you can measure the loss and check the fit in your own panels before committing. Per-order test reports are standard, and sample reports can be provided in advance for tender documentation.
Tell us the platform and the quantity. An engineer checks the part against your switch and software version before quoting — if it will not work, we say so.
Goes to our engineers and the quotation desk together. Replies come from sales@topnetsystem.com, usually within one working day.