Enter for the full results page · Esc to close

Rear MPO in, different-count MPO out, inside a cassette.
The cassette version of the conversion harness: high-count MPO at the rear, several lower-count MPOs on the front panel. It is how you make a legacy 24-fibre or 12-fibre trunk plant serve base-8 parallel optics without stranding a third of the fibres you already paid to install.
Assemblies are built on US Conec MTP® ferrules and terminated in a controlled environment, then measured fibre by fibre. Interferometry checks the three geometry parameters that decide whether a multi-fibre ferrule mates properly — radius of curvature, apex offset and fibre height — and every end face is inspected and graded to IEC 61300-3-35 before the dust cap goes on.
Fibre count, fibre type, polish, polarity, gender, jacket rating, leg length and overall length are all build options rather than catalogue limits. Use the selector above to configure the exact assembly and the specification table will follow your choices; the measured test report ships with the cable.
| Conversion | 1 × MPO-24 rear → 3 × MPO-12 (8F loaded) front |
|---|---|
| Fiber Count | 24F |
| Ports | 1 rear / 3 front |
| Fiber Type | OS2 single-mode, G.652.D — Corning SMF-28 Ultra |
| Insertion Loss | ≤ 0.35 dB |
| Return Loss | ≥ 60 dB |
| Connector Polish | APC — 8° angled, green housing |
| Polarity | Straight-through position mapping, documented per module |
| Wavelength | 1310 / 1550 nm |
| Typical Insertion Loss | 0.25 dB |
| Loss Grade | Standard |
| Format | LGX-compatible cassette, 1×LGX footprint |
|---|---|
| Rear Gender | Female (unpinned) MPO adapter |
| Front Gender | Female (unpinned) MPO adapters |
| Housing | Cold-rolled steel, black powder coat |
| Labelling | Position map printed on the module face |
| Operating Temp | -10 °C to +60 °C |
| Compliance | IEC 61754-7, TIA-604-5, RoHS |
| Jacket Colour | Yellow |
| Optical Test | 100% — every fibre measured for insertion loss and return loss before shipment |
|---|---|
| Ferrule Geometry | Interferometer-verified: radius of curvature, apex offset and fibre height to IEC 61755-3 |
| End-Face Inspection | Every ferrule inspected and graded to IEC 61300-3-35 |
| Test Report | Per-fibre measured data supplied with the assembly, traceable to the serial number |
| Connector Source | US Conec MTP® ferrules; genuine-brand or FOT MPO to your preference |
| Customisation | Fibre count, type, polish, polarity, gender, jacket, leg length and overall length built to order |
| Lead Time | Stock configurations 3–5 days; custom builds 7–10 days |
| Warranty | 3 years |
| Part Number | Configuration | Fibre count | Availability |
|---|---|---|---|
| FOT-MPO-CONVCAS | Standard configuration | 24F | Build to order |
| FOT-MPO-CONVCAS-24T212 | Conversion: 24F → 2 × 12F | 24F | Build to order |
| FOT-MPO-CONVCAS-212T38 | Conversion: 2 × 12F → 3 × 8F | 24F | Build to order |
| FOT-MPO-CONVCAS-16T28 | Conversion: 16F → 2 × 8F | 16F | Build to order |
| FOT-MPO-CONVCAS-32T48 | Conversion: 32F → 4 × 8F | 32F | Build to order |
| FOT-MPO-CONVCAS-657A1 | Fibre type: G.657.A1 bend-insensitive | 24F | Build to order |
| FOT-MPO-CONVCAS-657A2 | Fibre type: G.657.A2 bend-insensitive | 24F | Build to order |
| FOT-MPO-CONVCAS-OM3 | Fibre type: OM3 multimode | 24F | Build to order |
| FOT-MPO-CONVCAS-OM4 | Fibre type: OM4 multimode | 24F | Build to order |
Part numbers are indicative. Send us the fibre count, type, polish, polarity, gender, jacket and length and we confirm the exact build code on the quotation.
Insertion loss and return loss recorded for every fibre, not sampled.
Interferometer data on ferrule radius, apex offset and fibre height.
Every end face checked against IEC 61300-3-35 before packing.
Dust-capped, coiled on a reel or in a bag with the test report and pulling sock.
Parallel 40G/100G/400G/800G backbone between spine, leaf and top-of-rack panels.
Rail-optimised accelerator fabrics where one switch port breaks out to several GPUs.
Pre-terminated backbone that installs in hours instead of days, with the loss budget known up front.
Loopbacks, attenuators and inspection for proving ports before the link goes live.
Because base-12 trunk plant and base-8 optics do not divide evenly. A 12-fibre trunk feeding 8-fibre transceivers strands four fibres per connector — a third of what you installed. A conversion module re-groups three 8-fibre connections out of two 12-fibre trunks and you use everything.
One extra mated MPO pair, so about 0.35 dB worst case per module. Weigh that against stranding a third of the fibre in an installed trunk — on almost any existing plant, the module wins.
Both ends carry a printed label with the part number, fibre count, fibre type, polarity type and the serial number, and breakout legs are individually numbered. Tell us your own labelling convention on the RFQ and we print to it — it costs nothing and it saves an afternoon at installation.
Yes. We supply qualification samples so you can measure the loss and check the fit in your own panels before committing. Per-order test reports are standard, and sample reports can be provided in advance for tender documentation.
Tell us the platform and the quantity. An engineer checks the part against your switch and software version before quoting — if it will not work, we say so.
Goes to our engineers and the quotation desk together. Replies come from sales@topnetsystem.com, usually within one working day.