Optical Communication Products · Shenzhen, China
Tel: +86 0755 23766314  ·  marketing@fotfiberoptic.com
Request a Quote

MPO/MTP to LC / SC / FC Harness Cable

SKU: FOT-MPO-HARN · Harness, Hydra & Conversion

Fan one MPO out to duplex LC, SC or FC legs.

12FFibre count
6 × LC duplexBreakout legs
≤ 0.35 dBInsertion loss
0.5–2 mLeg length
Fibre count
12F → 6 × duplex8F → 4 × duplex16F → 8 × duplex24F → 12 × duplex
Breakout connector
LC duplexLC unibootSC duplexFC simplexMDC / SN (VSFF)
Fibre type
OS2 single-mode (G.652.D)G.657.A1 bend-insensitiveG.657.A2 bend-insensitiveOM3 multimodeOM4 multimodeOM5 wideband
Loss grade
Standard lossLow lossExtra low loss
Polish
APC (angled, 8°)UPC / PC (flat)
MPO gender
Female (unpinned)Male (pinned)
Leg length
1.0 m0.5 m1.5 m2.0 m
Jacket
LSZH 3.0 mmOFNR riserOFNP plenumArmored (steel spiral)
Length
5 m1 m3 m10 m20 m30 m50 m100 m
Configured part numberFOT-MPO-HARN
Ships worldwide
Built to your configuration
3-year warranty

Product Overview

A harness takes the parallel MPO trunk and fans it out to the duplex connectors your transceivers actually have. One MTP at the panel end, a furcated set of LC, SC or FC legs at the equipment end — the standard way to serve duplex 10G/25G/100G optics from a parallel backbone.

Assemblies are built on US Conec MTP® ferrules and terminated in a controlled environment, then measured fibre by fibre. Interferometry checks the three geometry parameters that decide whether a multi-fibre ferrule mates properly — radius of curvature, apex offset and fibre height — and every end face is inspected and graded to IEC 61300-3-35 before the dust cap goes on.

Fibre count, fibre type, polish, polarity, gender, jacket rating, leg length and overall length are all build options rather than catalogue limits. Use the selector above to configure the exact assembly and the specification table will follow your choices; the measured test report ships with the cable.

Technical SpecificationsUpdates with your selection

Optical
Fiber Count12F
Connector AMTP® / MPO 12-fibre, female
Connector B6 × LC duplex
Fiber TypeOS2 single-mode, G.652.D — Corning SMF-28 Ultra
Wavelength1310 / 1550 nm
Insertion Loss≤ 0.35 dB
Return Loss≥ 60 dB
Connector PolishAPC — 8° angled, green housing
PolarityType B mapping, LC legs numbered and labelled
Typical Insertion Loss0.25 dB
Loss GradeStandard
Mechanical & Environment
GenderFemale (unpinned) MPO end
Leg Cable2.0 mm LSZH round furcation
Breakout Leg Length1.0 m
Cable JacketLSZH round, 3.0 mm
Jacket ColourYellow
Furcation BodyMoulded strain-relief transition with pulling sock
Length5 m (custom lengths to 500 m)
Min. Bend Radius10 × cable OD dynamic, 5 × static
Crush Resistance≥ 1000 N / 100 mm
Tensile StrengthShort term 100 N / long term 30 N
Operating Temp-10 °C to +60 °C
Storage Temp-40 °C to +75 °C
ComplianceIEC 61754-7, TIA-604-5 (FOCIS-5/10), RoHS
Flame RatingIEC 60332-1 LSZH
Testing, Quality & Supply
Optical Test100% — every fibre measured for insertion loss and return loss before shipment
Ferrule GeometryInterferometer-verified: radius of curvature, apex offset and fibre height to IEC 61755-3
End-Face InspectionEvery ferrule inspected and graded to IEC 61300-3-35
Test ReportPer-fibre measured data supplied with the assembly, traceable to the serial number
Connector SourceUS Conec MTP® ferrules; genuine-brand or FOT MPO to your preference
CustomisationFibre count, type, polish, polarity, gender, jacket, leg length and overall length built to order
Lead TimeStock configurations 3–5 days; custom builds 7–10 days
Warranty3 years

Ordering Information

Part NumberConfigurationFibre countAvailability
FOT-MPO-HARNStandard configuration12FBuild to order
FOT-MPO-HARN-8FFibre count: 8F → 4 × duplex8FBuild to order
FOT-MPO-HARN-16FFibre count: 16F → 8 × duplex16FBuild to order
FOT-MPO-HARN-24FFibre count: 24F → 12 × duplex24FBuild to order
FOT-MPO-HARN-LCUBBreakout connector: LC uniboot12FBuild to order
FOT-MPO-HARN-SCBreakout connector: SC duplex12FBuild to order
FOT-MPO-HARN-FCBreakout connector: FC simplex12FBuild to order
FOT-MPO-HARN-VSFFBreakout connector: MDC / SN (VSFF)12FBuild to order

Part numbers are indicative. Send us the fibre count, type, polish, polarity, gender, jacket and length and we confirm the exact build code on the quotation.

Quality & What's in the Box

Measured Fibre by Fibre

Insertion loss and return loss recorded for every fibre, not sampled.

Geometry Verified

Interferometer data on ferrule radius, apex offset and fibre height.

Inspected & Graded

Every end face checked against IEC 61300-3-35 before packing.

Packaging

Dust-capped, coiled on a reel or in a bag with the test report and pulling sock.

Typical Applications

Data Centre Spine & Leaf

Parallel 40G/100G/400G/800G backbone between spine, leaf and top-of-rack panels.

AI / GPU Clusters

Rail-optimised accelerator fabrics where one switch port breaks out to several GPUs.

Structured Cabling

Pre-terminated backbone that installs in hours instead of days, with the loss budget known up front.

Test & Commissioning

Loopbacks, attenuators and inspection for proving ports before the link goes live.

Frequently Asked Questions

Harness or cassette — which should I use?

A harness is cheaper and has one less mated pair in the channel, so it costs you less loss. A cassette is tidier, lets you re-patch the LC side without touching the trunk, and keeps the MPO hidden away from day-to-day handling. Harness for fixed equipment feeds; cassette where the front side changes often.

Does the leg numbering follow the MPO position numbering?

Yes — leg 1 carries MPO positions 1 and 12 under Type B mapping, and every leg is printed with its number and the MPO positions it carries. Say so on the RFQ if you need a different mapping; we build to it and label accordingly.

Can I get LC uniboot legs?

Yes, and in a dense panel they are worth the small premium: one round cable per duplex leg instead of two zipcord halves, roughly half the volume in the manager, and switchable polarity at the connector. See our uniboot and VSFF connector guide.

How is the assembly labelled?

Both ends carry a printed label with the part number, fibre count, fibre type, polarity type and the serial number, and breakout legs are individually numbered. Tell us your own labelling convention on the RFQ and we print to it — it costs nothing and it saves an afternoon at installation.

Can I get free samples before ordering volume?

Yes. We supply qualification samples so you can measure the loss and check the fit in your own panels before committing. Per-order test reports are standard, and sample reports can be provided in advance for tender documentation.

Related MPO / MTP Products

Request a quote for this part

Tell us the platform and the quantity. An engineer checks the part against your switch and software version before quoting — if it will not work, we say so.

Goes to our engineers and the quotation desk together. Replies come from sales@topnetsystem.com, usually within one working day.