Linear Receive Optics (LRO)

Modules, Packaging & Form Factors

A half-way house between DSP modules and LPO: the DSP stays on the transmit side, the receive path goes linear.

Also called
half-retimed optics
Power saving
roughly 20–30% versus a full DSP module
Why it exists
the receive path is where linear operation is most forgiving
Interoperability
easier than LPO — the transmit waveform is still cleaned up
LRO: DSP on Transmit, Linear on Receive
Keep the clean launch waveform; give up the digital regeneration only on the way back

What Is Linear Receive Optics?

LRO removes the DSP from one direction only. The transmit path keeps its digital signal processing, so the light launched into the fibre is still a clean, retimed waveform. The receive path is linear: the photodiode output is amplified and passed straight to the host SerDes without digital regeneration.

It is a deliberate compromise, and a well-chosen one. Most of the interoperability difficulty with fully linear optics lives on the transmit side, because that is where a distorted host output turns directly into a distorted optical signal that somebody else's receiver has to cope with.

Why the Asymmetry Helps

Keep the transmit DSP and an LRO module launches a signal any compliant receiver can handle — including a conventional DSP module at the far end, from a different vendor, in a fabric nobody jointly qualified. That single property makes LRO deployable in mixed estates where full LPO is not.

The cost is that the saving is smaller: roughly 20 to 30 per cent of module power against LPO's 30 to 50. You are removing one of two DSP functions, so you recover something less than half the benefit — the receive-side DSP is generally the smaller of the two.

What the Host Has to Do

On receive, the host SerDes now sees a signal that has crossed the fibre, been converted by a photodiode and amplified, with nothing having cleaned it up. Its equalisation has to be good enough to recover that unaided.

Modern switch SerDes generally are, at short reach. What to check is whether the specific platform's receive equalisation has been characterised for linear operation — some vendors publish this, some do not, and ‘our SerDes are excellent’ is not the same as a measurement.

Where You Meet It

The same short-reach data-centre roles as LPO: in-rack and in-row at 400G and 800G. Vendors also use it as a stepping stone — ship LRO now, move to full LPO once host capability and interoperability testing catch up.

If you are weighing the two, the deciding question is usually not technical but organisational: can you guarantee that both ends of every link come from a qualified pairing? If yes, LPO saves more. If no, LRO is the version that survives contact with procurement.

LRO versus the alternatives

Transmit pathconventional DSP — retimed, regenerated
Receive pathlinear TIA straight to the host SerDes
Power savingroughly 20–30% of module power
Interoperabilityeasier than LPO — the far end sees a clean signal
Host requirementSerDes must equalise the received signal unaided
Also calledhalf-retimed optics

Questions about your project?

Send the specification and an engineer answers it — no obligation, and no sales sequence. If the answer is that you do not need what we sell, that is the answer you get.