OSFP

Modules, Packaging & Form Factors

An eight-lane pluggable form factor for 400G, 800G and 1.6T, designed from the start with a larger thermal envelope than QSFP-DD.

Lanes
8 electrical lanes
Speeds
400G (8×50G), 800G (8×100G), 1.6T (8×200G, as OSFP224)
Power envelope
higher than QSFP-DD — integral heatsink options
Backward compatible with QSFP?
not directly — an adapter is required
OSFP and QSFP-DD Side by Side
Eight lanes either way — the difference is thermal envelope against backward compatibility

What Is OSFP?

OSFP — Octal Small Form-factor Pluggable — is one of the two dominant high-speed pluggable form factors. Eight electrical lanes gives 400G at 50G per lane, 800G at 100G per lane, and 1.6T at 200G per lane in the OSFP224 variant.

It was specified with a slightly larger body than QSFP-DD, and that extra volume is the whole argument for it: more room for heat spreading, and a thermal path that can carry the 20 to 30 watts that 800G and 1.6T optics dissipate.

RHS and Flat-Top, and Why It Matters

Two mechanical variants matter in practice. OSFP with an integrated riding heat sink — RHS — puts the thermal interface on the module itself. Flat-top OSFP, sometimes called IHS, relies on a heat sink in the cage, which is what liquid-cooled and some high-density switch designs want.

They are not interchangeable. A flat-top module in a cage expecting a riding heat sink has no thermal path and will run hot — and the symptom is a module that works in the lab and throttles or errors in a full rack. Tell your supplier the switch model, not just the form factor.

What It Does Not Do

OSFP is not mechanically backward-compatible with QSFP or QSFP28. Where that matters, an OSFP-to-QSFP adapter exists and works, at the cost of a slot's worth of space and some thermal margin.

For an operator with a large installed base of 100G optics, that is a genuine disadvantage and is the main reason QSFP-DD still dominates general-purpose data centre switching.

Where You Meet It

OSFP dominates in AI and HPC fabrics, particularly NVIDIA InfiniBand and Spectrum-based Ethernet clusters, largely because of the thermal headroom. Check what a full switch does to your rack budget in the power and thermal calculator before finalising a design.

See our OSFP transceiver range across 400G, 800G and 1.6T.

OSFP reference

Full nameOctal Small Form-factor Pluggable
Lanes8
400G8 × 50G PAM4
800G8 × 100G PAM4
1.6T8 × 200G PAM4 (OSFP224)
Mechanical variantsRHS (riding heat sink) and flat-top / IHS
Backward compatibilitynone — OSFP-to-QSFP adapter available