Optical Communication Products · Shenzhen, China
Tel: +86 0755 23766314  ·  marketing@fotfiberoptic.com
Request a Quote

Fiber Pigtail

Fibre, Connectors & Cabling

A short length of fibre with a factory-terminated connector on one end and bare fibre on the other, for splicing into the plant.

One end
factory-polished connector
Other end
bare fibre for fusion splicing
Typical splice loss
about 0.1 dB
Why use one
factory termination beats field termination on loss and consistency
Why a Pigtail Beats a Field-Terminated Connector
The connector is made in a factory; only the splice happens on site

What Is a Fiber Pigtail?

A pigtail is half a patch cord: a connector, a short length of fibre — usually one to three metres of 900 µm tight buffer — and a bare end. It exists so that the connector can be made and polished in a factory under controlled conditions, then joined to the installed cable by a fusion splice on site.

That division of labour is the entire point. Everything that determines connector quality — apex offset, fibre height, radius of curvature, cleanliness during polish — is done on a machine and measured on an interferometer, not in a riser cupboard with a headtorch.

The Loss Arithmetic

The installed cable is stripped and cleaved, the pigtail is cleaved, and a fusion splicer arc-welds the two together. The joint costs about 0.1 dB and often much less on single-mode. The factory connector contributes about 0.25 dB when mated, so the total from cable to patch panel is roughly 0.35 dB.

Field-terminated connectors — mechanical splice-on types, or epoxy-and-polish — typically land between 0.5 and 0.75 dB, with a spread several times wider. Across a 96-fibre distribution frame that difference is the margin that decides whether the channels close. Run it through the link budget calculator if the design is marginal.

Ribbon pigtails apply the same logic twelve fibres at a time: a mass-fusion splicer joins a whole ribbon in one arc, which is how a 288-fibre closure gets terminated in a shift rather than a week. Each joint is protected in a 40 or 60 mm heat-shrink sleeve and laid into a tray with enough slack that it can be re-worked later without disturbing its neighbours.

What Goes Wrong

Splice quality is not self-evident. A splicer's estimated loss is an image-processing guess from the arc, not a measurement, and it can be optimistic on a core-offset joint. Anything that matters gets verified with an OTDR from both ends, which is exactly what Tier 2 testing is for.

The other recurring problem is bend radius in the splice tray. Coiling excess pigtail too tightly against the tray wall adds macrobend loss that appears at 1550 nm and not at 1310, which is a very confusing symptom until you know to look for it — see G.657.

Where You Meet It

Every distribution frame, splice closure, terminal box and FTTH cabinet. Available in single-mode and multimode with any connector and polish: our LC/UPC pigtails and SC/UPC pigtails are the usual choices for terminating outdoor cable.

Fibre pigtail reference

Constructionone factory-terminated connector, one bare fibre end
Typical length1 to 3 m
Buffer900 µm tight buffer, or 250 µm in ribbon form
Fusion splice lossabout 0.1 dB; often 0.02 to 0.05 dB on single-mode
Mated connector lossabout 0.25 dB standard, 0.12 dB low-loss grade
Connector plus spliceabout 0.35 dB total
Field-terminated connectortypically 0.5 to 0.75 dB, and far more variable
Splice protection40 or 60 mm heat-shrink sleeve, coiled in a tray
Ribbon pigtails12 fibres mass-fusion spliced in one operation

Questions about your project?

Send the specification and an engineer answers it — no obligation, and no sales sequence. If the answer is that you do not need what we sell, that is the answer you get.

Usually answered within one working day.