Multi-fiber trunk fanning out to 4–24 LC legs. Factory-terminated, 100% optically tested, compliant with IEC, TIA/EIA and Telcordia standards.
The LC-LC fanout (breakout) patch cord consolidates 4 to 24 fibers into one protected trunk that fans out to individual LC legs at each end — replacing a bundle of simplex jumpers with a single organized assembly that installs faster and routes cleaner.
Each leg is individually terminated and tested to the same ≤0.3 dB insertion-loss standard, with staggered or even-length breakouts, custom leg lengths and label schemes built to your rack plan. Branch diameters of 2.0/3.0 mm suit both patching and riser use.
Ideal for ODF-to-equipment cabling, backbone distribution and any application where fiber count is climbing but panel space and installation time are not.
≤ 0.3 dB across connector types for maximum optical power budget headroom.
Full optical inspection and IL/RL testing on every unit, with test data available.
IEC, TIA/EIA and Telcordia; UL OFNR and CPR fire-resistance rated jackets.
Reduced bend-sensitivity fiber available for tight routing and dense cabinets.
Connector, fiber grade, jacket, diameter, color and length built to your spec.
Standard items ship in 3–7 days with dedicated capacity for volume orders.
| Insertion Loss | ≤ 0.3 dB (all types) |
|---|---|
| Return Loss — SM UPC | ≥ 50 dB |
| Return Loss — SM APC | ≥ 60 dB |
| Return Loss — MM UPC | ≥ 30 dB |
| Fiber Height | -100 to +50 nm |
| Apex Offset | ≤ 50 nm |
| APC Angle | 8° ± 0.5° |
| Connector Options | LC/UPC, LC/APC, SC, FC, ST, E2000 |
|---|---|
| Fiber | OS2 · OM3 · OM4 |
| Configuration | 4F, 6F, 8F, 12F, 24F |
| Cable Diameter | Φ0.9 / Φ2.0 / Φ3.0 mm |
| Jacket Material | PVC / LSZH / OFNP / OFNR |
| Fire Rating | UL OFNR, CPR Eca |
| Standards | IEC, TIA/EIA, Telcordia |
High-density patching & SAN links
High-bandwidth transmission
Carrier networks and access
Reliable long-distance links
Yes — staggered leg lengths, per-leg color coding and printed label schemes are standard OEM options, so the assembly drops straight into your rack plan without on-site sorting.
UPC connectors have a domed end-face giving return loss ≥50 dB — ideal for most Ethernet and data links. APC connectors are polished at an 8° angle for ≥60 dB return loss, preferred for PON/CATV, RF-over-fiber and other reflection-sensitive systems.
Every assembly undergoes 100% optical inspection plus insertion- and return-loss testing to IEC, TIA/EIA and Telcordia standards. Test reports are available on request.
Yes — length, jacket color and material (PVC / LSZH / OFNP / OFNR), cable diameter (0.9 / 2.0 / 3.0 mm) and any connector combination are OEM/ODM customizable.
Standard configurations ship in 3–7 days with flexible MOQ. Custom OEM/ODM runs are quoted per project — send us your specs for a fast quotation.
Tell us the platform and the quantity. An engineer checks the part against your switch and software version before quoting — if it will not work, we say so.
Goes to our engineers and the quotation desk together. Replies come from sales@topnetsystem.com, usually within one working day.